Nicolas Cuello's profile

Failure analysis in globe valve

Fitness for Service analysis in Globe Valve of 2''

The main purpose of this study was to perform a failure analysis in a globe valve. The cause of failure was an excessive shear stress in the graphite seal.
For which it was initially reconstructed three-dimensionally, from the design drawings of the equipment, and then modeled by the finite element method using ANSYS. Within the study, the following analyses were performed: static and fluid mechanics with Fluent.
Force diagram of the valve
In this diagram it can be seen every piece of the valve and the forces involved. 
Stress distribution
The next figure shows the results of the stress distribution of the valve.
Velocity of the internal fluid in a 3D and 2D plane
The next figure shows the results of the velocity of the internal fluid.